SSF在改善冠状动脉CT图像质量中的应用

何川东, 刘启榆, 陈娇, 等. SSF在改善冠状动脉CT图像质量中的应用[J]. 临床心血管病杂志, 2015, 31(9): 960-964. doi: 10.13201/j.issn.1001-1439.2015.09.012
引用本文: 何川东, 刘启榆, 陈娇, 等. SSF在改善冠状动脉CT图像质量中的应用[J]. 临床心血管病杂志, 2015, 31(9): 960-964. doi: 10.13201/j.issn.1001-1439.2015.09.012
HE Chuandong, LIU Qiyu, CHEN Jiao, et al. The applicaton of SSF in improving image qulity of coronary CT angiography[J]. J Clin Cardiol, 2015, 31(9): 960-964. doi: 10.13201/j.issn.1001-1439.2015.09.012
Citation: HE Chuandong, LIU Qiyu, CHEN Jiao, et al. The applicaton of SSF in improving image qulity of coronary CT angiography[J]. J Clin Cardiol, 2015, 31(9): 960-964. doi: 10.13201/j.issn.1001-1439.2015.09.012

SSF在改善冠状动脉CT图像质量中的应用

详细信息
    通讯作者: 刘启榆,E-mail:lqy2225085@163.com
  • 中图分类号: R541.4

The applicaton of SSF in improving image qulity of coronary CT angiography

More Information
  • 目的:探讨冠脉运动追踪冻结平台(SSF)在改善64层螺旋CT冠状动脉图像质量中的应用价值。方法:回顾性分析行冠状动脉CT成像(CCTA)检查的121例患者的标准重建图像及基于SSF的运动校正图像,平均心率(HR)≤60次/min 39例,HR 60~70次/min 42例,HR>70次/min 40例。分析平均HR、HR变异及HR波动对冠状动脉图像质量的影响;分析同一平均HR时,运动校正前后冠状动脉图像质量的差异。结果:平均HR是影响冠状动脉图像质量的主要因素。HR≤60次/min时,SSF在改善右冠状动脉的图像质量中有价值;HR 60~70次/min时,SSF在改善右冠状动脉及左冠状动脉小血管的图像质量中有价值;HR>70次/min时,SSF能显著改善左右冠状动脉的图像质量。结论:SSF在改善冠状动脉的图像质量中有良好应用价值,特别是对高HR患者。
  • 加载中
  • [1]

    RITCHIE C J,GODWIN J D,CRAWFORD C R,et al. Minimum scan speeds for suppression of motion artifacts in CT[J]. Radiology,1992,185:37-42.

    [2]

    范丽娟,孙凤伟,张计旺,等.冠状动脉追踪冻结技术对不控制心率受试者CT冠状动脉成像质量的影响[J].中华放射学杂志,2014,48(2):105-108.

    [3]

    黄美萍,刘其顺,刘辉,等.多层螺旋CT冠状动脉成像质量及对冠状动脉病变诊断准确性的评价[J].中华放射学杂志,2006,40(9):984-987.

    [4]

    OHASHI K,ICHIKAWA K,HARA M,et al.Examination of the optimal temporal resolution required for computed tomography coronary angiography[J]. Radiol Phys Technol,2013, 6:453-460.

    [5]

    SEIFARTH H,WIENBECK S,PUSKEN M,et al.Optimal systolic and diastolic reconstruction windows for coronary CT angiography using dual-source CT[J].AJR Am J Roentgenol,2007,189:1317-1323.

    [6]

    NAGATANI Y,TAKAHASHI M,TAKAZAKURA R,et al. Multidetector-row computed tomography coronary angiography:optimization of image reconstruction phase according to the heart rate[J]. Circ J,2007, 71:112-121.

    [7]

    刘斌,赵红,吴兴旺,等.64层螺旋CT冠状动脉成像图像质量的相关影响因素分析(心脏体模模拟实验)[J].中华放射学杂志,2006,40(9):980-983.

    [8]

    SUN G, LI M, JIANG X S, et al.320-detector row CT coronary angiography:effects of heart rate and heart rate variability on image quality, diagnostic accuracy and radiation exposure[J].Br J Radiol,2012, 85:e388-e394.

    [9]

    赵红,刘斌,吴兴旺,等.64层螺旋CT冠状动脉成像质量的心率变化及其对图像质量的影响[J].实用放射学杂志,2007,23(2):145-149.

    [10]

    DING Z,FRIEDMAN M H.Quantification of 3-D coronary arterial motion using clinical biplane cineangiograms[J].Int J Card Imaging,2000,16:331-346.

    [11]

    PONTONE G,ANDREINI D,BARTORELLI A L,et al.Feasibility and accuracy of a comprehensive multidetector computed tomography acquisition for patients referred for balloon-expandable transcatheter aortic valve implantation[J].Am Heart J,2011,161:1106-1113.

    [12]

    FLOHR T G,BRUDER H,STIERSTORFER K,et al.Image reconstruction and image quality evaluation for a dual source CT scanner[J].Med Phys,2008,35:5882-5897.

    [13]

    LEIPSIC J,LABOUNTY T M,HAGUE C J,et al.Effect of a novel vendor-specific motion-correction algorithm on image quality and diagnostic accuracy in persons undergoing coronary CT angiography without rate-control medications[J]. J Cardiovasc Comput Tomogr,2012,6:164-171.

    [14]

    ROHKOHL C,BRUDER H,STIERSTORFER K,et al.Improving best-phase image quality in cardiac CT by motion correction with MAM optimization[J].Med Phys,2013,40:031901.

  • 加载中
计量
  • 文章访问数:  92
  • PDF下载数:  119
  • 施引文献:  0
出版历程
收稿日期:  2014-12-08
修回日期:  2015-03-20