心脏植入式电子装置感染预防的研究进展

王涛, 鲍慧慧, 程晓曙. 心脏植入式电子装置感染预防的研究进展[J]. 临床心血管病杂志, 2020, 36(8): 765-767. doi: 10.13201/j.issn.1001-1439.2020.08.018
引用本文: 王涛, 鲍慧慧, 程晓曙. 心脏植入式电子装置感染预防的研究进展[J]. 临床心血管病杂志, 2020, 36(8): 765-767. doi: 10.13201/j.issn.1001-1439.2020.08.018
WANG Tao, BAO Huihui, CHENG Xiaoshu. Research progress on measures to prevent infection in cardiac implantable electronic devices[J]. J Clin Cardiol, 2020, 36(8): 765-767. doi: 10.13201/j.issn.1001-1439.2020.08.018
Citation: WANG Tao, BAO Huihui, CHENG Xiaoshu. Research progress on measures to prevent infection in cardiac implantable electronic devices[J]. J Clin Cardiol, 2020, 36(8): 765-767. doi: 10.13201/j.issn.1001-1439.2020.08.018

心脏植入式电子装置感染预防的研究进展

  • 基金项目:

    江西省科技计划专项(No:2016ACG70012)

详细信息
    通讯作者: 程晓曙,E-mail:xiaoshumenfan@126.com
  • 中图分类号: R54

Research progress on measures to prevent infection in cardiac implantable electronic devices

More Information
  • 心脏植入式电子装置应用越来越广泛,但感染率居高不下。感染后不仅影响植入式电子装置的正常工作,而且严重危害患者的生命健康。预防感染发生,降低感染率,一直以来备受重视。本文对目前各种预防感染措施的有效性和不足等进行阐述,旨在为预防心脏植入式电子装置感染提供参考。
  • 加载中
  • [1]

    Mond HG,Proclemer A.The 11th world survey of cardiac pacing and implantable cardioverter-defibrillators:calendar year 2009——a World Society of Arrhythmia's project[J].Pacing Clin Electrophysiol,2011,34(8):1013-1027.

    [2]

    李赐恩,宋卫锋,王徐乐,等.起搏器感染后再次植入原起搏器和植入新起搏器的安全性比较分析[J].临床心血管病杂志,2017,33(4):353-355.

    [3]

    Blomstrom-Lundqvist C,Traykov V,Erba PA,et al.European Heart Rhythm Association (EHRA) international consensus document on how to prevent,diagnose,and treat cardiac implantable electronic device infections-endorsed by the Heart Rhythm Society (HRS),the Asia Pacific Heart Rhythm Society (APHRS),the Latin American Heart Rhythm Society (LAHRS),International Society for Cardiovascular Infectious Diseases (ISCVID),and the European Society of Clinical Microbiology and Infectious Diseases (ESCMID) in collaboration with the European Association for Cardio-Thoracic Surgery (EACTS)[J].Eur Heart J,2020,41(21):2012-2032.

    [4]

    Henrikson CA,Sohail MR,Acosta H,et al.Antibacterial envelope is associated with low infection rates after implantable cardioverter-defibrillator and cardiac resynchronization therapy device replacement:results of the Citadel and Centurion Studies[J].JACC Clin Electrophysiol,2017,3(10):1158-1167.

    [5]

    Gould PA,Gula LJ,Champagne J,et al.Outcome of advisory implantable cardioverter-defibrillator replacement:one-year follow-up[J].Heart Rhythm,2008,5(12):1675-1681.

    [6]

    Bloom HL,Constantin L,Dan D,et al.Implantation success and infection in cardiovascular implantable electronic device procedures utilizing an antibacterial envelope[J].Pacing Clin Electrophysiol,2011,34(2):133-142.

    [7]

    Traykov V,Bongiorni MG,Boriani G,et al.Clinical practice and implementation of guidelines for the prevention,diagnosis and management of cardiac implantable electronic device infections:results of a worldwide survey under the auspices of the European Heart Rhythm Association[J].Europace,2019,21(8):1270-1279.

    [8]

    Da CA,Kirkorian G,Cucherat M,et al.Antibiotic prophylaxis for permanent pacemaker implantation:a meta-analysis[J].Circulation,1998,97(18):1796-1801.

    [9]

    Klug D,Balde M,Pavin D,et al.Risk factors related to infections of implanted pacemakers and cardioverter-defibrillators:results of a large prospective study[J].Circulation,2007,116(12):1349-1355.

    [10]

    Alzahrani T,Liappis AP,Baddour LM,et al.Preoperative antibiotics and cardiovascular implantable electronic device infection:A cohort study in veterans[J].Pacing Clin Electrophysiol,2018,41(11):1513-1518.

    [11]

    Asundi A,Stanislawski M,Mehta P,et al.Prolonged antimicrobial prophylaxis following cardiac device procedures increases preventable harm:insights from the VA CART program[J].Infect Control Hosp Epidemiol,2018,39(9):1030-1036.

    [12]

    Krahn AD,Longtin Y,Philippon F,et al.Prevention of arrhythmia device infection trial:The PADIT Trial[J].J Am Coll Cardiol,2018,72(24):3098-3109.

    [13]

    Senaratne JM,Jayasuriya A,Irwin M,et al.A 19-year study on pacemaker-related infections:a claim for using postoperative antibiotics[J].Pacing Clin Electrophysiol,2014,37(8):947-954.

    [14]

    Zywiel MG,Daley JA,Delanois RE,et al.Advance pre-operative chlorhexidine reduces the incidence of surgical site infections in knee arthroplasty[J].Int Orthop,2011,35(7):1001-1006.

    [15]

    Qintar M,Zardkoohi O,Hammadah M,et al.The impact of changing antiseptic skin preparation agent used for cardiac implantable electronic device (CIED) procedures on the risk of infection[J].Pacing Clin Electrophysiol,2015,38(2):240-246.

    [16]

    Schweizer M,Perencevich E,Mcdanel J,et al.Effectiveness of a bundled intervention of decolonization and prophylaxis to decrease Gram positive surgical site infections after cardiac or orthopedic surgery:systematic review and meta-analysis[J].BMJ,2013,346:f2743.

    [17]

    Zheng Q,Di Biase L,Ferrick KJ,et al.Use of antimicrobial agent pocket irrigation for cardiovascular implantable electronic device infection prophylaxis:Results from an international survey[J].Pacing Clin Electrophysiol,2018,41(10):1298-1306.

    [18]

    Desimone DC,Chahal AA,Desimone CV,et al.International survey of knowledge,attitudes,and practices of cardiologists regarding prevention and management of cardiac implantable electronic device infections[J].Pacing Clin Electrophysiol,2017,40(11):1260-1268.

    [19]

    Lakkireddy D,Valasareddi S,Ryschon K,et al.The impact of povidone-iodine pocket irrigation use on pacemaker and defibrillator infections[J].Pacing Clin Electrophysiol,2005,28(8):789-794.

    [20]

    Koerber SM,Loethen T,Turagam M,et al.Noninvasive tissue adhesive for cardiac implantable electronic device pocket closure:the TAPE pilot study[J].J Interv Card Electrophysiol,2019,54(2):171-176.

    [21]

    胡金柱,洪葵,巨珍珍,等.一种预防起搏器感染的镍钛合金材料制备方法:江西,CN109321909A[P].2019-02-12.